0
0 Cart (empty)
Vantage Pro 2 Envoy Plus Wireless Weather Station with active ventilation

Vantage Pro 2 Envoy Plus Wireless Weather Station with active ventilation

€1,839.00 (tax incl.) (€1,532.50 VAT excl.)
Delivery in 1 to 5 days in Europa

Davis Instruments Vantage Pro2 Envoy Plus Professional Weather Station, 6161EU. A complete version of the Vantage Pro 2 weather stations, this weather station has the added benefit of solar probes (pyranometer and UV sensor) and a 24-hour actively ventilated radiation shelter. The presence of the pyranometer allows the calculation of potential evapotranspiration.

Reference
6161EU
Available (2 Items)

Vantage Pro 2 Plus Envoy wireless weather station with active ventilation from Davis Instruments, part number 6161EU. The connection between the external sensors (ISS) and the console is made by radio waves on the frequency 868.0 - 868.6 MHz with a range of 300 meters maximum.

For its proper functioning, this station must be supplemented with a datalogger (6510USB - 6510SER - Wifilogger - Meteopiethernet)

The Weather Envoy 6316EU console from Davis Instruments is a console without LCD screen which will allow you to receive data from a weather station or an ISS Vantage Pro 2 and send them to a computer (with the WeatherLink interface not supplied ) and so you can place your LCD console in another room. The Weather Envoy console offers the same measurement and data storage features as the Vantage Pro 2 LCD console. The Weather Envoy console is also compatible with the Davis Vantage Vue station and can be mounted against a wall. The connection between the external sensors (ISS) and the console is made by radio waves on the frequency 868.0 - 868.6 MHz with a range of 300 meters on sight.

The sensor suite (ISS) is very robust and can be mounted on a mast (tube) or on a wooden pole. A dual sensor for measuring outdoor temperature and humidity is placed in a standardised radiation shelter with 24-hour active ventilation. The active ventilation allows a better accuracy of the outdoor temperature and humidity measurements 24 hours a day. The rain gauge is equipped with a tipping bucket system (single bucket system) for measuring precipitation and bird spikes. The wind vane - anemometer can be detached from the ISS and installed on a roof, for example, with its 12-metre cable. The ISS is equipped with a UV sensor to measure the UV index and a pyranometer to measure solar radiation and evapotranspiration (used in agriculture).  


The Davis Vantage Pro 2 6161EU weather station comes with:

    An console and power supply. 6316EU
    Outdoor Sensor Suite (ISS) 6328OV (3V CR123 Lithium backup battery not included)
    An anemometer - wind vane with 12 metres of cable.
    A fixing kit.
    A UV probe
    A pyranometer
    A support for the UV probe and the pyranometer.
    A 24-hour active ventilation system.
    Instructions for use in French can be downloaded from this product sheet.

And allows to measure:

    Indoor temperature - Resolution 0,1°C.
    Outdoor temperature - Resolution 0.1°C.
    Indoor humidity - Resolution: 1%.
    Outdoor humidity - Resolution: 1%.
    Atmospheric pressure - Resolution: 0.1 hPa.
    Heat index - Resolution 1°C.
    Dew point - Resolution 1°C.
    Precipitation - Resolution 0.2 mm.
    Feeling temperature - Resolution 1°C.
    Wind speed from 3 to 241 Km/h - Resolution 1 Km/h.
    Wind direction - Resolution 1°.
    Evapotranspiration (ET)
    Solar radiation in W/m² - Resolution 1 M/m².
    UV index - Resolution 0.1.
    UV dose - Resolution 0.1 MED < 20 - 1 MED > 20.

Note on warranty: There is no warranty for the batteries of the active ventilation.

Miscellaneous
Size
378 x 327 x 594 mm
Weight
7.9 kg
Warranty
2 ans
Radio frequency
868.0 - 868.6 MHz FHSS, inférieur à 8mW
Wireless range
300m à vue, 60 à 120m avec des obstacles
Wind
Units of measurement
mph, km/h, m/s, Nœud
Resolution
1 mph, 1 km/h, 0.5 m/s, ou 1 Nœud
Accuracy
±3 km/h
Measuring range
3 à 290 km/h
Measurement frequency
2.5 à 3 secondes
Wiring
12m de longueur, max recommandé 165m
Measurement principle
Godets à vent, capteur à effet Hall
Wind direction
Resolution
16 points (22,5°) sur la rose des vents, 1° à affichage numérique
Accuracy
±3°
Measuring range
0 à 360°
Measurement frequency
2.5 à 3 secondes
Measurement principle
Girouette avec potentiomètre
Atmospheric pressure
Units of measurement
inin Hg, mm Hg, hPa/mb
Resolution
0.01inin Hg, 0.1 mm Hg, 0.1 hPa/mb
Accuracy
±1.0 hPa
Measuring range
540 à 1100 hPa
Measurement frequency
1 minute
UV Index
Resolution
0.1
Accuracy
± 5% de l'échelle totale
Measuring range
Indice 0 à 16
Measurement frequency
50 sec à 1 min (5 minutes lorsqu'il fait sombre)
Drift
jusqu'à ± 2% par an
Outside temperature
Units of measurement
°C ou °F
Resolution
0.1
Accuracy
±0.3°C
Measuring range
-40°C à 65°C
Measurement frequency
10 à 12 secondes
Measurement principle
PN junction silicon diode
Windchill
Resolution
1
Accuracy
±1
Measurement frequency
10 à 12 secondes
Measurement principle
Calcul, formule de Osczevski (1995)
Inside temperature
Units of measurement
°C ou °F
Resolution
0.1
Accuracy
±0.5°C
Measuring range
0 à 60°C
Measurement frequency
1 minute
Receiving console
Composition
plastique ABS résistant aux UV
Measure
Temperature ; Humidity ; Atmospheric pressure
Power supply
Adaptateur secteur AC, 5 VDC, 300 mA, réglementé
Size
245 mm x 156 mm x 41 mm
Weight
0.85 kg
Power supply autonomy
1 mois (approximativement)
Operating temperature
0 à 60°C
Current consumption
0,9 mA en moyenne, 30 mA en crête, (ajoutez 120 mA pour les lampes d'affichage, ajoutez 0,125 mA pour chaque émetteur sans fil optionnel reçu par la console) à 4 - 6 VDC
Backup power supply
3 piles LR14 (non fournies)
Display
LCD, rétroéclairable
Integrated Sensor Suite (ISS)
Composition
plastiques ABS et ASA résistants aux UV
Measure
Temperature ; Humidity ; Wind speed ; Wind direction ; Rainfall ; UV ; Solar radiation ; Windchill ; Wind gusts
Power supply
panneau solaire, accumulateur 10F, pile de secours
Power supply autonomy
8 mois sans ensoleillement, plus de 2 ans en fonction de l'ensoleillement
Operating temperature
-40 à 65°C
Current consumption
5 mA (en moyenne) de 4 à 6 VDC pour l'ISS seulement. 10 mA en moyenne entre la console et l'ISS
Backup power supply
pile Lithium 3V CR123 (non fournie)
UV radiation dose
Units of measurement
MEDs
Resolution
0.1 MEDs à 19.9 MEDs, tous les 1 MED au dessus de 19.9 MEDS
Accuracy
±5% pour le total journalier
Measurement frequency
50 sec à 1 min
Drift
jusqu'à ± 2% par an
Outdoor humidity
Units of measurement
% HR
Resolution
1%
Accuracy
±2%
Measuring range
1 à 100% RH
Measurement frequency
50 secondes à 1 minute
Measurement principle
Condensateur à film
Drift
inférieur à 0.25% par an
Solar radiation
Units of measurement
W/m²
Resolution
1 W/m²
Accuracy
± 5% de l'échelle totale
Measuring range
0 à 1800 W/m2
Drift
jusqu'à ± 2% par an
Rainfall
Units of measurement
mm ou pouces
Resolution
0.2 mm ou 0.01inin
Accuracy
Pour les intensités de pluie jusqu'à 100 mm/h : ±3% du total ou +0.25 mm au plus
Measurement frequency
20 à 24 secondes
Measurement principle
Auget basculant
Rain receiving surface
214 cm2
Rainfall rate
Units of measurement
mm/h ou inin/h
Resolution
0.1 mm ou 0.01 inin/h
Accuracy
±5% pour les intensités inférieures à 250 mm/h
Measuring range
0 à 762 mm/h
Measurement frequency
20 à 24 secondes
Indoor humidity
Units of measurement
% HR
Resolution
1 % HR
Accuracy
±2%
Measuring range
1 à 100% HR
Measurement frequency
1 minute
Evapotranspiration
Units of measurement
mm ou pouces
Resolution
0.1 mm ou 0.01inin
Accuracy
0.25 mm ou ±5%
Measuring range
Journalier jusqu'à 832,2 mm, mensuel et annuel jusqu'à 1999.9 mm
Measurement frequency
1 heure
Measurement principle
Equation de Penman modifiée, telle que mise en œuvre par CIMIS (California Irrigation Management Information System)
Dew point
Units of measurement
°C ou °F
Resolution
1
Accuracy
±1.5°C
Measuring range
-76° à 54°C
Measurement frequency
10 à 12 secondes
Measurement principle
L'équation de l'OMM à l'égard de la saturation de l'air humide sur l'eau