Vantage Pro 2 Envoy Plus Wireless Weather Station with active ventilation
Davis Instruments Vantage Pro2 Envoy Plus Professional Weather Station, 6161EU. A complete version of the Vantage Pro 2 weather stations, this weather station has the added benefit of solar probes (pyranometer and UV sensor) and a 24-hour actively ventilated radiation shelter. The presence of the pyranometer allows the calculation of potential evapotranspiration.
Vantage Pro 2 Plus Envoy wireless weather station with active ventilation from Davis Instruments, part number 6161EU. The connection between the external sensors (ISS) and the console is made by radio waves on the frequency 868.0 - 868.6 MHz with a range of 300 meters maximum.
For its proper functioning, this station must be supplemented with a datalogger (6510USB - 6510SER - Wifilogger - Meteopiethernet)
The Weather Envoy 6316EU console from Davis Instruments is a console without LCD screen which will allow you to receive data from a weather station or an ISS Vantage Pro 2 and send them to a computer (with the WeatherLink interface not supplied ) and so you can place your LCD console in another room. The Weather Envoy console offers the same measurement and data storage features as the Vantage Pro 2 LCD console. The Weather Envoy console is also compatible with the Davis Vantage Vue station and can be mounted against a wall. The connection between the external sensors (ISS) and the console is made by radio waves on the frequency 868.0 - 868.6 MHz with a range of 300 meters on sight.
The sensor suite (ISS) is very robust and can be mounted on a mast (tube) or on a wooden pole. A dual sensor for measuring outdoor temperature and humidity is placed in a standardised radiation shelter with 24-hour active ventilation. The active ventilation allows a better accuracy of the outdoor temperature and humidity measurements 24 hours a day. The rain gauge is equipped with a tipping bucket system (single bucket system) for measuring precipitation and bird spikes. The wind vane - anemometer can be detached from the ISS and installed on a roof, for example, with its 12-metre cable. The ISS is equipped with a UV sensor to measure the UV index and a pyranometer to measure solar radiation and evapotranspiration (used in agriculture).
The Davis Vantage Pro 2 6161EU weather station comes with:
An console and power supply. 6316EU
Outdoor Sensor Suite (ISS) 6328OV (3V CR123 Lithium backup battery not included)
An anemometer - wind vane with 12 metres of cable.
A fixing kit.
A UV probe
A pyranometer
A support for the UV probe and the pyranometer.
A 24-hour active ventilation system.
Instructions for use in French can be downloaded from this product sheet.
And allows to measure:
Indoor temperature - Resolution 0,1°C.
Outdoor temperature - Resolution 0.1°C.
Indoor humidity - Resolution: 1%.
Outdoor humidity - Resolution: 1%.
Atmospheric pressure - Resolution: 0.1 hPa.
Heat index - Resolution 1°C.
Dew point - Resolution 1°C.
Precipitation - Resolution 0.2 mm.
Feeling temperature - Resolution 1°C.
Wind speed from 3 to 241 Km/h - Resolution 1 Km/h.
Wind direction - Resolution 1°.
Evapotranspiration (ET)
Solar radiation in W/m² - Resolution 1 M/m².
UV index - Resolution 0.1.
UV dose - Resolution 0.1 MED < 20 - 1 MED > 20.
Note on warranty: There is no warranty for the batteries of the active ventilation.
- Miscellaneous
-
- Size
- 378 x 327 x 594 mm
- Weight
- 7.9 kg
- Warranty
- 2 ans
- Radio frequency
- 868.0 - 868.6 MHz FHSS, inférieur à 8mW
- Wireless range
- 300m à vue, 60 à 120m avec des obstacles
- Wind
-
- Units of measurement
- mph, km/h, m/s, Nœud
- Resolution
- 1 mph, 1 km/h, 0.5 m/s, ou 1 Nœud
- Accuracy
- ±3 km/h
- Measuring range
- 3 à 290 km/h
- Measurement frequency
- 2.5 à 3 secondes
- Wiring
- 12m de longueur, max recommandé 165m
- Measurement principle
- Godets à vent, capteur à effet Hall
- Wind direction
-
- Resolution
- 16 points (22,5°) sur la rose des vents, 1° à affichage numérique
- Accuracy
- ±3°
- Measuring range
- 0 à 360°
- Measurement frequency
- 2.5 à 3 secondes
- Measurement principle
- Girouette avec potentiomètre
- Atmospheric pressure
-
- Units of measurement
- inin Hg, mm Hg, hPa/mb
- Resolution
- 0.01inin Hg, 0.1 mm Hg, 0.1 hPa/mb
- Accuracy
- ±1.0 hPa
- Measuring range
- 540 à 1100 hPa
- Measurement frequency
- 1 minute
- UV Index
-
- Resolution
- 0.1
- Accuracy
- ± 5% de l'échelle totale
- Measuring range
- Indice 0 à 16
- Measurement frequency
- 50 sec à 1 min (5 minutes lorsqu'il fait sombre)
- Drift
- jusqu'à ± 2% par an
- Outside temperature
-
- Units of measurement
- °C ou °F
- Resolution
- 0.1
- Accuracy
- ±0.3°C
- Measuring range
- -40°C à 65°C
- Measurement frequency
- 10 à 12 secondes
- Measurement principle
- PN junction silicon diode
- Windchill
-
- Resolution
- 1
- Accuracy
- ±1
- Measurement frequency
- 10 à 12 secondes
- Measurement principle
- Calcul, formule de Osczevski (1995)
- Inside temperature
-
- Units of measurement
- °C ou °F
- Resolution
- 0.1
- Accuracy
- ±0.5°C
- Measuring range
- 0 à 60°C
- Measurement frequency
- 1 minute
- Receiving console
-
- Composition
- plastique ABS résistant aux UV
- Measure
- Temperature ; Humidity ; Atmospheric pressure
- Power supply
- Adaptateur secteur AC, 5 VDC, 300 mA, réglementé
- Size
- 245 mm x 156 mm x 41 mm
- Weight
- 0.85 kg
- Power supply autonomy
- 1 mois (approximativement)
- Operating temperature
- 0 à 60°C
- Current consumption
- 0,9 mA en moyenne, 30 mA en crête, (ajoutez 120 mA pour les lampes d'affichage, ajoutez 0,125 mA pour chaque émetteur sans fil optionnel reçu par la console) à 4 - 6 VDC
- Backup power supply
- 3 piles LR14 (non fournies)
- Display
- LCD, rétroéclairable
- Integrated Sensor Suite (ISS)
-
- Composition
- plastiques ABS et ASA résistants aux UV
- Measure
- Rainfall ; UV ; Solar radiation ; Windchill ; Wind gusts ; Temperature ; Humidity ; Wind speed ; Wind direction
- Power supply
- panneau solaire, accumulateur 10F, pile de secours
- Power supply autonomy
- 8 mois sans ensoleillement, plus de 2 ans en fonction de l'ensoleillement
- Operating temperature
- -40 à 65°C
- Current consumption
- 5 mA (en moyenne) de 4 à 6 VDC pour l'ISS seulement. 10 mA en moyenne entre la console et l'ISS
- Backup power supply
- pile Lithium 3V CR123 (non fournie)
- UV radiation dose
-
- Units of measurement
- MEDs
- Resolution
- 0.1 MEDs à 19.9 MEDs, tous les 1 MED au dessus de 19.9 MEDS
- Accuracy
- ±5% pour le total journalier
- Measurement frequency
- 50 sec à 1 min
- Drift
- jusqu'à ± 2% par an
- Outdoor humidity
-
- Units of measurement
- % HR
- Resolution
- 1%
- Accuracy
- ±2%
- Measuring range
- 1 à 100% RH
- Measurement frequency
- 50 secondes à 1 minute
- Measurement principle
- Condensateur à film
- Drift
- inférieur à 0.25% par an
- Solar radiation
-
- Units of measurement
- W/m²
- Resolution
- 1 W/m²
- Accuracy
- ± 5% de l'échelle totale
- Measuring range
- 0 à 1800 W/m2
- Drift
- jusqu'à ± 2% par an
- Rainfall
-
- Units of measurement
- mm ou pouces
- Resolution
- 0.2 mm ou 0.01inin
- Accuracy
- Pour les intensités de pluie jusqu'à 100 mm/h : ±3% du total ou +0.25 mm au plus
- Measurement frequency
- 20 à 24 secondes
- Measurement principle
- Auget basculant
- Rain receiving surface
- 214 cm2
- Rainfall rate
-
- Units of measurement
- mm/h ou inin/h
- Resolution
- 0.1 mm ou 0.01 inin/h
- Accuracy
- ±5% pour les intensités inférieures à 250 mm/h
- Measuring range
- 0 à 762 mm/h
- Measurement frequency
- 20 à 24 secondes
- Indoor humidity
-
- Units of measurement
- % HR
- Resolution
- 1 % HR
- Accuracy
- ±2%
- Measuring range
- 1 à 100% HR
- Measurement frequency
- 1 minute
- Evapotranspiration
-
- Units of measurement
- mm ou pouces
- Resolution
- 0.1 mm ou 0.01inin
- Accuracy
- 0.25 mm ou ±5%
- Measuring range
- Journalier jusqu'à 832,2 mm, mensuel et annuel jusqu'à 1999.9 mm
- Measurement frequency
- 1 heure
- Measurement principle
- Equation de Penman modifiée, telle que mise en œuvre par CIMIS (California Irrigation Management Information System)
- Dew point
-
- Units of measurement
- °C ou °F
- Resolution
- 1
- Accuracy
- ±1.5°C
- Measuring range
- -76° à 54°C
- Measurement frequency
- 10 à 12 secondes
- Measurement principle
- L'équation de l'OMM à l'égard de la saturation de l'air humide sur l'eau
You might also like
WeatherLink USB Datalogger
Lithium Battery 3 Volt
WiFi Logger v2 for Vantage Pro 2/Vantage Vue
Meteo-Pi Ethernet for Vantage Pro...
10 other products in the same category: