The HOBO® U24-001 Freshwater Conductivity Logger provides highly accurate water quality data. It measures and records conductivity and temperatures in streams, lakes and other freshwater sources. This logger is recommended for monitoring aquifers for saltwater intrusion and road and agricultural runoff.

Reference
U24-001
Preorder

The HOBO® U24-001 Freshwater Conductivity Logger provides highly accurate water quality data. It measures and records conductivity and temperatures in streams, lakes and other freshwater sources. This logger is recommended for monitoring aquifers for saltwater intrusion and road and agricultural runoff.   The non-contact HOBO® U24 sensor minimises measurement errors due to drift. And the logger features software-based drift compensation. It has a waterproof coating to effectively protect the sensor and can be easily deployed to monitor water purity and pollutant impact.  

Benefits:

  • Non-contact sensor for long life and minimisation of measurement errors due to drift
  • Easy access to the sensor for cleaning and air bubble removal
  • Compatible with the HOBO® U24-001 shuttle for easy and reliable data retrieval and transport
  • HOBOware Pro software allows calibration of start and end points to enable conversion to specific conductance and salinity

Product sheet U24001 (FR)

Download (505.7KB)

Manual U24001 (FR)

Download (1.77MB)
Miscellaneous
Composition
Delrin®, epoxy, stainless steel retaining ring, polypropylene, Buna rubber O-ring, titanium pentoxide (inert coating on sensor)
Power supply
3.6 V lithium battery
Size
3.18 x 16.5 cm
Weight
193 g
Power supply autonomy
3 years (with one recording every minute)
Operating temperature
-2°C to 36°C frost free
Protection
IP68
Memory
18,500 temperature and conductivity measurements for one conductivity range used, 14,400 sets of measurements for both ranges (64 KB total memory)
Recording interval
1 second to 18 hours, fixed or multiple rate sampling, up to 8 user defined sampling intervals
Max depth
70 m
Temperature
Measure
Temperature
Resolution
0.01°C
Accuracy
0.1°C
Measuring range
-2°C to 36°C
Conductivity
Measure
Conductivity
Resolution
1 μS/cm
Measuring range
Calibrated conductivity: Low range: 0 to 1,000 μS/cm, High range: 0 to 10,000 μS/cm; extended measurements: Low range: 0 to 2,500 μS/cm, High range: 0 to 15,000 μS/cm
Drift
Less than 3% sensor drift per year, excluding drift due to fouling
Response time
1 second at 90% change (in water)